FREE SHIPPING ON ORDERS OVER $100 within the 48 Contiguous United States!

PR5.0 | Small Area Flushmount Ceiling Air Filter

200 CFM - 1 unit covers approximately 200 sq. ft. Flush mount system with 3 filtration stages. Installation hardware included.

First Years Filters Included!


SKU: PR5.0-B

Regular price
$1,145.00
Sale price
$1,145.00

Accepted Payments - MasterCard, VISA, American Express, Discover, Amazon Payments, PayPal
Instruction Manual

Description

The PR5.0 ceiling flushmount commercial air cleaner dust collector is an extremely attractive, self-contained dust collection system that is light-weight, easy to install and very affordable.

200 CFM - 1 unit covers approximately 1,600 cubic feet.
Includes installation hardware and all filters required for the first year!

The PR5.0 Flushmount Air Cleaner is designed to drop into a suspended ceiling. It replaces either 1 - 2' x 4' tile or 2 - 2' x 2' tiles from the suspended ceiling. In order to install the PR5.0 flushmount air cleaner easily the clearance above the suspended ceiling needs to be at least 8" and is recommended that the air cleaner is installed in areas that do not exceed an 8 foot ceiling height. The weight of the system does not rest on the ceiling grids but is secured above the suspended ceiling to a permanent structure such as a joist or beam. All filters on the 5.0FM Flushmount are accessible from the intake grill on the face of the system. 1 unit recommended for every 200 square feet.

How does the PR5.0 work?...

3 Filter System for Excellent Clean Air Results

  • Stage 1 - Pre-Filter - The pre-filter removes larger particles such as lint, hair, dust, and pollen. The pre filter is important because it removes the larger particles and it also helps prolong the life of the HEPA filter. Essentially, the pre filter is the first line of defense in maintaining your system; therefore promoting better indoor air quality. 
    Pre-filters cannot be washed and must be changed monthly.
  • Stage 2 - Carbon FilterThe activated carbon filter removes odors by absorbing the odor molecules into the filter. Since the activated carbon can only absorb a certain amount of molecules, it will stop working once it is full. Therefore, the carbon filters must be properly maintained. 
    The Carbon Filters cannot be washed and should be changed every 2 months.
  • Stage 3 - HEPA FilterThe HEPA filter removes the very small particles, such as smoke, dust mites, spores, mold spores, pollen, etc. The HEPA filter is an extremely important filter and when used and maintained properly will dramatically improve your indoor air quality.  
    The HEPA filter cannot be washed and should be changed annually.

The PR5.0 Flush mount HEPA Filter System uses a powerful blower to draw the air from smoke-filled areas. As the air is drawn through the high-efficiency filter media, 95% of the tobacco smoke particles are removed on each pass. The clean air that is constantly discharged into the area is refreshing and remarkably free of tobacco smoke and other contaminants. This is particularly beneficial in lounges and restaurants, because it reduces the need for segregated smoking areas. Practically all of the dust, dirt, pollen and other contaminant particles are removed from the air passing though the air cleaner. Even the microscopic airborne particles are trapped. Everyone prefers breathing air that's been cleaned of the many pollutants that can cause discomfort and stuffiness. Plus, lowering the pollen, spores and fungi count helps reduce the problems caused by these pollutants.

The PR5.0 is Available with Optional Ultraviolet Germicidal Lamps!

UV Bulb for commercial air cleaners

Why Optional Ultraviolet Germicidal Lamps in Commercial Air Cleaners? It is well know that ultraviolet germicidal lamps can destroy any microorganism that comes in contact with its powerful UV-C rays. As a microbe passes through UV-C, the light penetrates directly into the organism's nucleus disrupting the molecular bonds of it's "DNA". This breakage renders the microbe unable to reproduce and shortly thereafter the organism dies, leaving no offspring. This method is recommended by the Centers for Disease Control for its germicidal effects. The destruction of germs and bacteria by germicidal ultraviolet light is accomplished quickly and effectively. Filters trap particulate, and only when germs are attached to particulate, can the germs be trapped. The use of UV-C along with a highly efficient filtering media provides a truly clean, virus & bacteria free environment.

Specifications

PR5.0 Flush Mount Air Cleaner Specifications

Capacity Up to 200 Sq. Ft.
Single Speed 200 CFM
Sound Level 58 dB @ 5'
Installation Options Flushmount - Fits into 2 - 2' x 2' or 1 - 2' x 4' ceiling tile
Dimensions 46-1/2" L x 23-3/4" W x 7" H
Cabinet Construction Aluminum
Shipping Weight 45 lbs.
Electrical .74 amps | 120V
Power Cord 7' long | 3 prong grounded plug
Three Filter System Includes 1 Year Supply of Filters;
(1) - 6" HEPA Filter
(6) - 1/2" Activated Carbon Filters
(12) - 1/2" Pre-Filters
Warranty All Systems carry a lifetime Blower/Motor Warranty*
Certifications All electrical components and fan motor are UL Listed and CSA Certified
NOTE: 8" clearance above drop ceiling required. Install by removing ceiling tile and dropping unit in. Plug in or hard wire. Installation hardware included
*Lifetime Blower/Motor warranty applies if filters are changed as required and are purchased from Pure n Natural Systems, Inc.