Restore steady cold water in minutes
- Fixes “too warm/too cold” water by replacing the worn cold‑control.
- Replacement part for the PWC‑400—no guessing on wiring or capillary length.
- Pre‑assembled sensing bulb & capillary for quick swap and reliable cycling.
In the Box & Installation
-
Included: (1) CL4‑9531 cold thermostat with attached capillary/bulb;
-
Install (summary):
-
- Unplug the cooler; shut off water.
- Remove access panel; note thermostat wiring.
- Gently withdraw sensing bulb from the cold‑tank well; avoid bending sharply.
- Install the new thermostat; place bulb fully into the well (good contact).
- Reconnect wiring; set dial to mid‑range; reassemble.
- Restore power/water; allow 15–30 min for temperature to stabilize; adjust as needed.
FAQs
Is CL4‑9531 the correct thermostat for every PWC model?
No, CL4‑9531 is for the PWC‑400 cold circuit. Other models (PWC‑1000/1500/3500, etc.) use different controls. Please contact us with your model/serial.
What symptoms point to a bad cold thermostat?
Water stays warm, compressor never turns on, or runs continuously and ices the tank/coil. If wiring and charge are OK, the cold control is often the fix.
Do I need sealant on the sensing bulb?
Use the factory method (bulb fully seated in the well). If your unit used thermal paste or a clip, reuse/replace per Replacement instructions.
Need help now?
Call 1-800-237-9199, start a live chat, request a call back, or contact us