Smokemaster X11Q | Flush-Mount Commercial Electronic Smoke Eater - 500-1100 CFM

The Smokemaster X-11Q Electronic Smoke Eater quietly captures both airborne particles and gaseous odors and contaminants. It's ideal for cigar and cigarette smoke removal in cigar bars, restaurants, and lounges. Effective in areas up to 1,000 sq. ft.  Read More...

NOTE: The X11Q has not been tested for compliance with California Air Resource Board requirements and may not be shipped to California.

SKU: X11Q-W

Regular price
$3,295.00
Sale price
$3,295.00

The Smokemaster X11Q Self-Contained Electronic Smoke Eater fits flush-mounted into any 2' x 4' drop ceiling tile. Ideal for smoking areas up to 1,000 square feet.

If you're ready to get serious about air cleaning, then you'll want to check out the Smokemaster X-11Q. The Smokemaster X-11Q Smoke Eater air cleaner features a high-efficiency electrostatic cell designed to capture both particulate and gaseous contaminants. Contaminant particles, such as those in tobacco smoke, receive an electrical charge as they pass into the electronic cell and are then attracted to oppositely charged collector plates, where they are held, similar to the way that metal filings collect to a magnet. The air vent provides dilution control of gaseous contaminants. Activated carbon post-filtration adsorbs odors and gases to further freshen the air. The attractive grille fits flush with the ceiling and is completely inconspicuous. The cabinet is hidden in the unused space above the drop ceiling tile.

How does the Smokemaster X-11Q Electronic Air Cleaner work?...

Stage 1 - Metal Mesh Pre-Filter
The X11Q prefilter captures large particles such as hair, lint & pollen before they can enter the electronic cell.
The pre-filter is washable but should be replaced after repeated use.

Optional Heavy Duty Polytron Pre-Filter
The super-strong, heavy-duty Polytron pre-filter will help protect the electronic cell more diligently than the standard pre-filter because it captures more particles.Ā Ā It's especially helpful when dealing with "wet" or "misty" smoke.

Stage 2 - Electronic Cells
A process called ā€œElectrostatic Precipitationā€ traps over 97% of airborne contaminants on each pass through the X11Q. The ionizing section of the electronic cell electrically charges individual pollution particles. The electrostatic charge forces them to adhere to the oppositely charged collector plates.
The electronic cells must be washed periodically to maintain efficient performance.

Stage 3 - Carbon Post Filter
Carbon helps to removeĀ odors, VOCs, and gases providing a cleaner, odor-free air discharge. Includes 2 carbon filters for each side.Ā 
Carbon cannot be washed - filters should be replaced every 3-4 months.

Airflow is important too!

Coanda Airflow in the Smokemaster X11Q

The X-11Q air cleaning success is due to the "Coanda Aerodynamic Principle". Effective 360Ā° airflow gently and evenly distributes clean air and returns dirty air to the unit. Because of its unique 4-way method of air re-circulation, the X11Q gets the maximum amount of contaminated air to the machine most efficiently. More air reaches the Smokemaster while eliminating annoying drafts. This eliminates "stuffy" air pockets and creates people-comfort as well as much better air cleaning results!

Features & Benefits of the Smokemaster X-11Q Smoke Eater

  • High Efficiency - Removes dust, smoke, pollen, and other particles using high-efficiency electronic collector cells.
  • Quiet - Three-speed controller is standard and allows for quiet operation without sacrificing effectiveness. It's ideal for private offices, conference rooms, or other areas where noise may be a concern.
  • Easy Installation - Special mounting brackets simplify the installation and do not require any additional space above the cabinet height of 13-5/8".
  • Economical - Permanent electronic collector cells assure low operating costs by eliminating costly filter replacements. Moreover, because collector cells offer no airflow restriction, only limited horsepower is necessary, thus reducing noise and electrical draw.
  • Comprehensive - The Smokemaster X-11Q Smoke Eater Includes 2 Carbon Post Filters for odor control.

Ideal applications for the Smokemaster X-11Q Smoke Eater include: Smoking Lounges, Hookah Bars, Restaurants, Conference Rooms, Computer Rooms, Executive Offices, Taverns, Bowling Alleys, Pool Halls, Nightclubs, Bars and more!

Smokemaster X-11Q Electronic Smoke Eater Specifications

Capacity Up to 1,000 Sq. Ft.
3 Speed High - 1100 CFM | Medium - 900 CFM | Low - 500 CFM
Installation Options Flushmount - Fits into (1) - 2' x 4' ceiling tile or (2) - 2' x 2' ceiling tiles
Dimensions 46-3/4" (L) x 22-3/4" (W)Ā  x 13-5/8" (H)
Cabinet Sturdy, corrosion-resistant steel - Off-White or Black
Weight Shipping - 107 lbs. | Installed - 83 lbs.
Electrical 120V, 60 Hz - Hardwire
Current & Power Consumption High - 2.6 Amps | Medium - 2.2 Amps | Low - 1.9 Amps
Sound Level dB(A) High - 69 | Medium - 59 | Low - 51
Electronic Cell Collection Area 105.8 square feet
Efficiency Up to 97% per ASHRAE
Warranty 1 year limited warranty
Certifications UL & CSA Listed
X11Q Owner's Manual Smokemaster X11Q Commercial Air Cleaner Owner's Manual
NOTE: 14" clearance above drop ceiling required. Install by removing a ceiling tile and dropping the unit in. Hardwire.
Please complete the following information. We'll get your quote to you within 24 hours.Ā  If you're not sure about what Smoke Eater(s) you need, we'll be happy to provide you with a recommendation. You can fill out our Smoke Eater Recommendation form here.Ā Ā You can also use our CFM Calculator to determineĀ the optimalĀ CFM requirements for your specific application.

Recently viewed products

Pure Rewards

Members-Only Bonuses Earn 1% Back & More

Sign Up For Free